WI-NK-01, -02
- Working temperature and position: 50 °C (H/V)
- Working pressure: PN 16
- Metrological class:
Irrigation flow meters are designed for measurement of volume of contaminated water, espacially water which used for irrigation of arable fields and for measurement of volume of fine sewage.
- insert are removable with out dismantling water meters bodies from pipelines
| Item | |
nominal volumetric flow rate |
m3/h |
nominal diameter |
mm |
body length |
mm |
weight |
kg |
| Item | WI-NK-01, -02 | WI-NK-01, -02 | WI-NK-01, -02 | WI-NK-01, -02 | WI-NK-01, -02 | WI-NK-01, -02 | WI-NK-01, -02 | |
nominal volumetric flow rate |
m3/h |
30 | 50 | 90 | 125 | 175 | 250 | 450 |
nominal diameter |
mm |
50 | 65 | 80 | 100 | 125 | 150 | 200 |
body length |
mm |
200 | 200 | 225 | 250 | 250 | 300 | 350 |
weight |
kg |
9 | 10 | 12 | 16 | 20 | 25 | 38 |
remote volume read-out (NK)
- possibility of mounting on horizontal, vertical and inclined pipelines,
- counter of roller-pointer type housed on airtight casing,
- drive transfer on to the counter through a magnetic cluth,
- measuring inserts indentical for all sizes, which facilitates repairs and storage of parts,
- flow meters are produced with metallic (01 type) or plastic casing (02 type),
- counter protected by a paddlocked cover(metallic casings).