RS 125

The RS 125 contactor starter is made in a fireproof casing and allows for controlling one 90kW (500V) maximum power engine or two 45kW (500V) maximum power engines.
The apparatus is equipped with safety devices protecting against: short-circuits, load asymmetry, overload, main channel low insulation resistance, short circuits, high resistance and control circuit interruptions, high earthing resistance, incorrect supply voltage phase sequence (option).
The operation status of internal circuits and tripping of safety devices are signalled by means of LED indicators. The starter is also equipped with easy to read digital current meter, one for each output.

Technical data

Item
Rated voltage Un
V
nominal dc
A
total input current ar R, S, T contactors
A
making capacity at Ue=500V in utilization category AC3
kW
overload protection adjustment range
A
1-phase auxiliary voltage
V
main channel BZU adjusment resistance
kOhm
dimensions with inlets (width x height x depth)
mm
Weight
kg
degree of protection of enclosure
-
certified with mark
-
certificate number
-
Item RS 125
Rated voltage Un
V
400, 500, 690, 50 Hz
nominal dc
A
125 A or 2x63
total input current ar R, S, T contactors
A
≤250 (loop-through 125)
making capacity at Ue=500V in utilization category AC3
kW
90 or 2x45
overload protection adjustment range
A
30 ÷150A with 150/5A transformers or 10 ÷50A with 50/5A transformers
1-phase auxiliary voltage
V
24, 42, 50 Hz
main channel BZU adjusment resistance
kOhm
50
dimensions with inlets (width x height x depth)
mm
1000x785x540
Weight
kg
210
degree of protection of enclosure
-
IP 54
certified with mark
-
CE 1453, IM2(IM1) Ex d [ia] I
certificate number
-
KDB 06ATEX006X

Information about types are available in catalogue.

Diagram


Application

The contactor starters are designed for controlling and powering electrical engines of mining driver systems from three-phase supply networks with the transformer's insulated neutral point on the secondary side.
The contactor starters meet to requirements of the European Directive 94/9/EC (ATEX) for equipment in group I, category M2, and can be used in methane and coal dust exsplosion hazardous areas of underground mines.  

Design

The contactor starters are made in a flameproof housing. Devices are fitted with protective devices against:
  • short circuits,
  • load asymmetry,
  • overload,
  • main channel low insulation resistance,
  • short circuits, high resistance and control circuit interruptions,
  • high earthing resistance
  • incorrect power voltage phase sequence (optionally).

The starters can optionally be fitted with phase sequence control system which is specifically important when powering pumps as incorrect engine rotation may cause damage to the device.

Trade contact

Apator Mining Sp. z o.o.

 

Al. Roździeńskiego 188
40-203 Katowice, Poland

Head of Sales Department

Al. Roździeńskiego 188 40-203 Katowicefax +48 (32) 259-68-62
Name:Krzysztof Skroch
Function:Head of Sales Department
Phone:+48 32 784 23 63
Mobile phone:+48 506 009 190
Fax:+48 32 259 68 62
 
Name:Marek Barbach
Function:Sales Department Manager
Phone:+48 32 784 23 62
Mobile phone:+48 507 129 151
Name:Jakub Smołka
Phone:+48 32 784 23 57
Mobile phone:+48 507 129 151
Name:Korneliusz Kuczera
Phone:+48 32 784 23 64
Mobile phone:+48 500 002 676

Copyright © 2009-2010 Apator SA. All rights reserved.Created by VOBACOM