RS 63, RS 63D, RS 63R

The RS 63, RS 63D, RS 63R contactor starters are made in a flameproof housing. RS 63, RS 63R are single output devices and allow for controlling and powering one 45kW (500V) maximum power engine. RS 63R also allows reverse operation of the engine. RS 63D is a double output device and allows for controlling and powering one 45kW (500V) maximum power engine or two 22 kW (500V) maximum power engines.
The apparatuses are equipped with safety devices protecting against: short-circuits, load asymmetry, overload, main channel low insulation resistance, short circuits, high resistance and control circuit interruptions, high earthing resistance, incorrect supply voltage phase sequence (option).

Technical data

Item
Rated voltage Un
V
nominal dc
A
total input current ar R, S, T contactors
A
making capacity at Ue=500V in utilization category AC3
kW
1-phase auxiliary voltage
V
main channel BZU adjusment resistance
kOhm
dimensions with inlets (width x height x depth)
mm
Weight
kg
degree of protection of enclosure
-
certified with mark
-
certificate number
-
Item RS 63, RS 63R RS 63D
Rated voltage Un
V
400, 500, 690, 50 Hz 400, 500, 690, 50 Hz
nominal dc
A
70 70 or 2 x 35
total input current ar R, S, T contactors
A
125 (loop-through 62) 125 (loop-through 62)
making capacity at Ue=500V in utilization category AC3
kW
45 45 or 2x 22
1-phase auxiliary voltage
V
24,42, 50 Hz 24,42, 50 Hz
main channel BZU adjusment resistance
kOhm
50 50
dimensions with inlets (width x height x depth)
mm
805x680x450 805x680x450
Weight
kg
140 140
degree of protection of enclosure
-
IP 54 IP 54
certified with mark
-
CE 1453, I M2 Ex d [ia] I CE 1453, I M2 Ex d [ia] I
certificate number
-
KDB 06ATEX268X KDB 06ATEX268X

Information about types are available in catalogue.

Application

The contactor starters are designed for controlling and powering electrical engines of mining driver systems from three-phase supply networks with the transformer's insulated neutral point on the secondary side.
The contactor starters meet to requirements of the European Directive 94/9/EC (ATEX) for equipment in group I, category M2, and can be used in methane and coal dust exsplosion hazardous areas of underground mines.  

Diagram

RS 63, RS 63R
 
 RS 63D
 

 

Design

The contactor starters are made in a flameproof housing. Devices are fitted with protective devices against:
  • short circuits,
  • load asymmetry,
  • overload,
  • main channel low insulation resistance,
  • short circuits, high resistance and control circuit interruptions,
  • high earthing resistance
  • incorrect power voltage phase sequence (optionally).

The starters can optionally be fitted with phase sequence control system which is specifically important when powering pumps as incorrect engine rotation may cause damage to the device.

Trade contact

Apator Mining Sp. z o.o.

 

Al. Roździeńskiego 188
40-203 Katowice, Poland

Head of Sales Department

Al. Roździeńskiego 188 40-203 Katowicefax +48 (32) 259-68-62
Name:Krzysztof Skroch
Function:Head of Sales Department
Phone:+48 32 784 23 63
Mobile phone:+48 506 009 190
Fax:+48 32 259 68 62
 
Name:Marek Barbach
Function:Sales Department Manager
Phone:+48 32 784 23 62
Mobile phone:+48 507 129 151
Name:Jakub Smołka
Phone:+48 32 784 23 57
Mobile phone:+48 507 129 151
Name:Korneliusz Kuczera
Phone:+48 32 784 23 64
Mobile phone:+48 500 002 676

Copyright © 2009-2010 Apator SA. All rights reserved.Created by VOBACOM