Control device USln-*, USIw-*, USIOn-*, USIOw-*
USIO devices are designed to operate in underground mines attributed to class "a", "b", "c" of methane explosion hazard and to class "A" or "B" of coal dust explosion hazard. USI devices are designed to operate in underground mines attributed to class "a" of methane explosion hazard and to class "A" of coal dust explosion hazard. Spark-safe USI*-* control devices are produced with two types of housing:
USI*-* control device operates in two modes:
- IP54 class protection (USIn-* and USIw-*),
- flameproof (USIOn-* and USIOw-*).
USI*-* control device operates in two modes:
- 1D mode - the system monitors control line with operating contact with a diode,
- 2 D mode - the system monitors control line with switching contact with two diodes.
Technical data
| Item | |
external dimensions |
mm |
rated supply voltage |
V |
permissible range of supply voltage changes |
V |
maximum power consumption |
VA |
parameters of non-spark-safe relays for output circuits |
- |
number of contacts |
- |
contacts continuous load capacity |
- |
parameters of spark-safe output circuits |
- |
number of contacts |
- |
Maximum voltage amplitude of each of spark-safe circuits |
V |
Permissible diameter of connected conductors |
mm |
Maximum cross-section of conductors in terminal strip |
mm2 |
Maximum permissible serial resistance of input circuit (line) |
- |
Minimum permissible shunt resistance of input circuit (line) |
- |
Weight |
kg |
degree of protection of enclosure |
- |
catalogue number |
- |
certificate number |
- |
| Item | USIn-1 | USIn-2 | USIw-1 | USIw-2 | USIOn-1 | USIOn-2 | USIOw-1 | USIOw-2 | |
external dimensions |
mm |
272 x 266 x 111 | 272 x 266 x 111 | 272 x 266 x 111 | 272 x 266 x 111 | 445 x 278 x 205 | 445 x 278 x 205 | 445 x 278 x 205 | 445 x 278 x 205 |
rated supply voltage |
V |
24 or 42 | 24 or 42 | 100 ÷ 110, 127 ÷ 133, 220 ÷ 230 | 100 ÷ 110, 127 ÷ 133, 220 ÷ 230 | 24 or 42 | 24 or 42 | 100 ÷ 110, 127 ÷ 133, 220 ÷ 230 | 100 ÷ 110, 127 ÷ 133, 220 ÷ 230 |
permissible range of supply voltage changes |
V |
19,2 ÷ 28,8 or 33,6 ÷ 50,4 | 19,2 ÷ 28,8 or 33,6 ÷ 50,4 | 80 ÷ 126,5, 101,6 ÷ 159,6, 176 ÷ 276 | 80 ÷ 126,5, 101,6 ÷ 159,6, 176 ÷ 276 | 19,2 ÷ 28,8 or 33,6 ÷ 50,4 | 19,2 ÷ 28,8 or 33,6 ÷ 50,4 | 80 ÷ 126,5, 101,6 ÷ 159,6, 176 ÷ 276 | 80 ÷ 126,5, 101,6 ÷ 159,6, 176 ÷ 276 |
maximum power consumption |
VA |
13 | 13 | 13 | 13 | 13 | 13 | 13 | 13 |
parameters of non-spark-safe relays for output circuits |
- |
||||||||
number of contacts |
- |
2 (switching) | 2 (switching) | 2 (switching) | 2 (switching) | 2 (switching) | 2 (switching) | 2 (switching) | 2 (switching) |
contacts continuous load capacity |
- |
5 A 250 V (USIO – 8 A) for AC; 0,4 A 250V (USIO – 0,64 A) for DC | 5 A 250 V (USIO – 8 A) for AC; 0,4 A 250V (USIO – 0,64 A) for DC | 5 A 250 V (USIO – 8 A) for AC; 0,4 A 250V (USIO – 0,64 A) for DC | 5 A 250 V (USIO – 8 A) for AC; 0,4 A 250V (USIO – 0,64 A) for DC | 8 A 250 V for AC; 0,64 A 250 V for DC | 8 A 250 V for AC; 0,64 A 250 V for DC | 8 A 250 V for AC; 0,64 A 250 V for DC | 8 A 250 V for AC; 0,64 A 250 V for DC |
parameters of spark-safe output circuits |
- |
||||||||
number of contacts |
- |
2 (switching) | 2 (switching) | 2 (switching) | 2 (switching) | 2 (switching) | 2 (switching) | 2 (switching) | 2 (switching) |
Maximum voltage amplitude of each of spark-safe circuits |
V |
30 | 30 | 30 | 30 | 30 | 30 | 30 | 30 |
Permissible diameter of connected conductors |
mm |
11 ÷ 20 | 11 ÷ 20 | 11 ÷ 20 | 11 ÷ 20 | 14 ÷ 21 | 14 ÷ 21 | 14 ÷ 21 | 14 ÷ 21 |
Maximum cross-section of conductors in terminal strip |
mm2 |
4 | 4 | 4 | 4 | 4 | 4 | 4 | 4 |
Maximum permissible serial resistance of input circuit (line) |
- |
< 400 Ω | < 2 kΩ | < 400 Ω | < 2 kΩ | < 400 Ω | < 2 kΩ | < 400 Ω | < 2 kΩ |
Minimum permissible shunt resistance of input circuit (line) |
- |
> 2 kΩ | > 10 kΩ | > 2 kΩ | > 10 kΩ | > 2 kΩ | > 10 kΩ | > 2 kΩ | > 10 kΩ |
Weight |
kg |
4,6 | 4,6 | 4,6 | 4,6 | 35 | 35 | 35 | 35 |
degree of protection of enclosure |
- |
IP54 | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 | IP54 |
catalogue number |
- |
||||||||
certificate number |
- |
KDB 05ATEX177 | KDB 05ATEX177 | KDB 05ATEX177 | KDB 05ATEX177 | KDB 06ATEX211 | KDB 06ATEX211 | KDB 06ATEX211 | KDB 06ATEX211 |
2D
Versions
Type markings
Trade contact
Apator Mining Sp. z o.o.
Al. Roździeńskiego 188
40-203 Katowice, Poland
Head of Sales Department
Al. Roździeńskiego 188 40-203 Katowicefax +48 (32) 259-68-62Name:Krzysztof Skroch Function:Head of Sales Department Phone:+48 32 784 23 63 Mobile phone:+48 506 009 190 Fax:+48 32 259 68 62 |
Name:Marek Barbach Function:Sales Department Manager Phone:+48 32 784 23 62 Mobile phone:+48 507 129 151 |
Name:Jakub Smołka Phone:+48 32 784 23 57 Mobile phone:+48 507 129 151 |
Name:Korneliusz Kuczera Phone:+48 32 784 23 64 Mobile phone:+48 500 002 676 |