Temperature limitors WT-12… WT-30
The purpose of temperature limiters WT-12..., WT-30... is temperature control of elements of structures in selected places, e.g. on machine housings, conveyor structures or on elements of compressor units. The temperature limiters may be installed in rooms of grade "a", "b"and "c" of methane explosion hazard and of class "A" or "B" of coal dust explosion hazard. They may be applied for co-operation with spark-safe circuits.
They are manufactured in varieties:
- WT-12N, WT-30N - contact,
- WT-12D, WT-30D - with a diode incorporated in series.
Differences of structures:
- limiters WT-12... have a M12x1,25 thread
- limiters WT-30... have a M30x1,5 thread
| Item | |
cable length |
m |
external dimensions |
mm |
maximum parameters on terminals of a spark-safe circuit |
- |
Temperature parameters of limiters |
- |
weight with conductor of 1,5 m |
kg |
weight with conductor of 3,0 m |
kg |
outlet conductor |
- |
degree of protection of enclosure |
- |
certificate number |
- |
| Item | WT-12N/WT-12D | WT-30N/WT-30D | |
cable length |
m |
1,5 or 3 ** | 1,5 or 3 ** |
external dimensions |
mm |
33 x 30 x 60 (without conductor) | 41 x 36 x 52 (without conductor) |
maximum parameters on terminals of a spark-safe circuit |
- |
Ui=60 V, Ii=0,5 A, Pi=10 W, Ci=100 pF/m, Li=1 µH/m | Ui=60 V, Ii=0,5 A, Pi=10 W, Ci=100 pF/m, Li=1 µH/m |
Temperature parameters of limiters |
- |
45/30, 55/40, 65/45, 75/55, 85/60, 95/70, 105/80 ºC (tolerance ± 5ºC) | 45/30, 55/40, 65/45, 75/55, 85/60, 95/70, 105/80 ºC (tolerance ± 5ºC) |
weight with conductor of 1,5 m |
kg |
0,26 | 0,30 |
weight with conductor of 3,0 m |
kg |
0,44 | 0,48 |
outlet conductor |
- |
2x1,5 mm2, of diameter Ø8 mm | 2x1,5 mm2, of diameter Ø8 mm |
degree of protection of enclosure |
- |
IP67 | IP67 |
certificate number |
- |
KDB 08ATEX286X | KDB 08ATEX286X |
*Temperature of activation (at which the warmed up contact gets opened), depending on the variety of execution
Temperature of recovery (when the cooled down contact gets closed) depending on the variety of execution
Temperature of recovery (when the cooled down contact gets closed) depending on the variety of execution
Apator Mining Sp. z o.o.
Al. Roździeńskiego 188
40-203 Katowice, Poland
Head of Sales Department
Al. Roździeńskiego 188 40-203 Katowicefax +48 (32) 259-68-62Name:Krzysztof Skroch Function:Head of Sales Department Phone:+48 32 784 23 63 Mobile phone:+48 506 009 190 Fax:+48 32 259 68 62 |
Name:Marek Barbach Function:Sales Department Manager Phone:+48 32 784 23 62 Mobile phone:+48 507 129 151 |
Name:Jakub Smołka Phone:+48 32 784 23 57 Mobile phone:+48 507 129 151 |
Name:Korneliusz Kuczera Phone:+48 32 784 23 64 Mobile phone:+48 500 002 676 |