ZT-155, ZT-155 U
The transformer units type ZT-155 and ZT-155U are manufactured in flameproof housings and equipped with the main transformer for 5.5kVA power rating. The units are equipped with two independent contactor circuits (outputs) and make it possible to supply e.g. lighting installations with single-phase voltage of 133V or 230V. Voltage change of the transformer unit primary side (500V or 1000V) and secondary one is performed by a user during its installation. Depending on the type, the relays used make it possible to control the unit by connecting the standard control circuit (Roff < 600 Ω) and „low ohm" circuit (Roff < 100 Ω). The control is also possible by using manipulators mounted on the transformer unit housing.
Technical data
| Item | |
rated primary voltage |
V |
rated secondary voltage |
V |
power |
kVA |
outside auxiliary voltages with leak control |
V |
rated current of discharge 133/230 V |
A |
dimensions with inlets (width x height x depth) |
mm |
Weight |
kg |
control relay and separator |
- |
outlet I and II overload protection |
- |
transformer primary/secondary voltage value indicator |
- |
catalogue number |
- |
certified with mark |
- |
certificate number |
- |
| Item | ZT-155U version 01 | ZT-155U version 02 | ZT-155U version 05 | ZT-155U version 06 | ZT-155 version 03 | ZT-155 version 04 | ZT-155 version 07 | ZT-155 version 08 | |
rated primary voltage |
V |
500 or 1000, 50/60 Hz | 500 or 1000, 50/60 Hz | 500 or 1000, 50/60 Hz | 500 or 1000, 50/60 Hz | 500 or 1000, 50/60 Hz | 500 or 1000, 50/60 Hz | 500 or 1000, 50/60 Hz | 500 or 1000, 50/60 Hz |
rated secondary voltage |
V |
133 or 230, 50/60 Hz | 133 or 230, 50/60 Hz | 133 or 230, 50/60 Hz | 133 or 230, 50/60 Hz | 133 or 230, 50/60 Hz | 133 or 230, 50/60 Hz | 133 or 230, 50/60 Hz | 133 or 230, 50/60 Hz |
power |
kVA |
5,5+0,1 or 5,5+0,2 | 5,5+0,1 or 5,5+0,2 | 5,5+0,1 or 5,5+0,2 | 5,5+0,1 or 5,5+0,2 | 5,5+0,1 or 5,5+0,2 | 5,5+0,1 or 5,5+0,2 | 5,5+0,1 or 5,5+0,2 | 5,5+0,1 or 5,5+0,2 |
outside auxiliary voltages with leak control |
V |
42, 100 VA | 42, 100 VA | 42, 200 VA | 42, 200 VA | 42, 100 VA | 42, 100 VA | 42, 200 VA | 42, 200 VA |
rated current of discharge 133/230 V |
A |
24 | 24 | 24 | 24 | 24 | 24 | 24 | 24 |
dimensions with inlets (width x height x depth) |
mm |
950 x 785 x 540 | 950 x 785 x 540 | 950 x 785 x 540 | 950 x 785 x 540 | 950 x 785 x 540 | 950 x 785 x 540 | 950 x 785 x 540 | 950 x 785 x 540 |
Weight |
kg |
245 | 245 | 245 | 245 | 245 | 245 | 245 | 245 |
control relay and separator |
- |
- | - | - | - | equipped | equipped | equipped | equipped |
outlet I and II overload protection |
- |
miniature circuit-breaker 25 A | miniature circuit-breaker 25 A | miniature circuit-breaker 25 A | miniature circuit-breaker 25 A | miniature circuit-breaker 25 A | miniature circuit-breaker 25 A | miniature circuit-breaker 25 A | miniature circuit-breaker 25 A |
transformer primary/secondary voltage value indicator |
- |
- | equipped | - | equipped | - | equipped | - | equipped |
catalogue number |
- |
AM-910141-01 | AM-910141-02 | AM-910141-05 | AM-910141-06 | AM-910141-03 | AM-910141-04 | AM-910141-07 | AM-910141-08 |
certified with mark |
- |
CE 1453, IM2 Ex d I | CE 1453, IM2 Ex d I | CE 1453, IM2 Ex d I | CE 1453, IM2 Ex d I | CE 1453, IM2 Ex d [ia] I | CE 1453, IM2 Ex d [ia] I | CE 1453, IM2 Ex d [ia] I | CE 1453, IM2 Ex d [ia] I |
certificate number |
- |
KDB 09ATEX083X | KDB 09ATEX083X | KDB 09ATEX083X | KDB 09ATEX083X | KDB 09ATEX083X | KDB 09ATEX083X | KDB 09ATEX083X | KDB 09ATEX083X |
Diagram
Application
Transformer units are assigned for feeding electric mining tools and lighting circuits with a decreased three-phase voltage of 133V or 230 V.
Transformers units meet to requirements of the European Directive 94/9/EC (ATEX) for equipment in group I, category M2, and can be used in methane and coal dust exsplosion hazardous areas of underground mines.
Transformers units meet to requirements of the European Directive 94/9/EC (ATEX) for equipment in group I, category M2, and can be used in methane and coal dust exsplosion hazardous areas of underground mines.
Design
The tranformers units are made in a flameproof housing. Devices are
fitted with protective devices against:
- short circuits,
- load asymmetry,
- overload,
- main channel low insulation resistance,
- short circuits, high resistance and control circuit interruptions,
- high earthing resistance
- incorrect power voltage phase sequence (optionally).
Trade contact
Apator Mining Sp. z o.o.
Al. Roździeńskiego 188
40-203 Katowice, Poland
Head of Sales Department
Al. Roździeńskiego 188 40-203 Katowicefax +48 (32) 259-68-62Name:Krzysztof Skroch Function:Head of Sales Department Phone:+48 32 784 23 63 Mobile phone:+48 506 009 190 Fax:+48 32 259 68 62 |
Name:Marek Barbach Function:Sales Department Manager Phone:+48 32 784 23 62 Mobile phone:+48 507 129 151 |
Name:Jakub Smołka Phone:+48 32 784 23 57 Mobile phone:+48 507 129 151 |
Name:Korneliusz Kuczera Phone:+48 32 784 23 64 Mobile phone:+48 500 002 676 |