PBS 00/100mm

 
  • option of fuse link state indication by neon indicator tube  
  • option of installing labelling clip  
  • option of installing insulating barrier
  • bottom terminal shroud labelling area

Technical data

Item
fuse-base size
-
Rated thermal current Ith
A
Rated voltage Un
V
Rated insulation voltage Ui
V
Rated frequency
Hz
rated power dissipation
W
peak current
kA
Mechanical durability
-
weight
kg
Protection degree
IP
Size of fuse links
-
Item PBS 00/100mm
fuse-base size
-
00
Rated thermal current Ith
A
160
Rated voltage Un
V
690
Rated insulation voltage Ui
V
1000
Rated frequency
Hz
50-60
rated power dissipation
W
12
peak current
kA
100
Mechanical durability
-
1600
weight
kg
0,75
Protection degree
IP
00
Size of fuse links
-
00

Construction

Silver plated contacts provide low power loss. Depending on clamp type,
PBS fuse bases enable user to connect circular or sector-shaped cables or cables with lug terminals. PBS fuse bases of size 1-3 could be equipped with additional fuse link shrouds providing protection degree of IP20. Additionally offered adapters enable to install PBS fuse bases of different sizes on common bus bar system.

Application

PBS fuse bases are designed for the distribution of electricity and protection against short circuits and overloads in three phase alternative current circuits with maximum operating voltage of 690 V. They are intended for direct installation on horizontal or vertical bus bar system. Due to their modern and compact design installing is easy and gives much saving of space in substations and distribution boards. Each type is suitable for top cable terminal connection when installed on horizontal bus bar system. Removal of the fuse link provides clearly noticeable, large isolating distance in the circuit. Easy installation of earthing devices is another advantage.

 

Operating conditions

  • to be installed in the room free of any dust, aggressive or explosive gases
  • altitude up to 2000 meters above sea level
  • outdoor - in cabinets with protection degree > IP 34
  • ambient temperature from -25°C to +55°C - but in case of use of disconnectors in temperature from +41°C to +45°C current value Ith should be reduced by 5% and within temperature range of +46°C to +55°C current value Ith should be reduced by 10% ,
  • relative humidity of the air should not be higher than 50% at temperature of +40°C

Versions

 Version  Designation  Part number
PBS 00/160 A     For installing on 100 mm bus bar system, cable terminal: 3 x S-bridge clamp, 3 x M8 screw PBS 00/100mm                         
 63-811627-011
PBS 00/160 A For installing on 100 mm bus bar system, cable terminal: 3 x S-bridge clamp, 3 x M8 screw, fuse link state indication by neon indicator tubes  PBS 00/100mm-W  63-811627-021
 PBS 00/160 A For installing on 100 mm bus bar system, cable terminal: 3 x V-shaped clamp  PBS 00/100mm-V  63-811627-031

 

 

PBS 00/100mm, PBS 00/100mm-W, PBS 00/100mm-V

 

 


 

 

Clamps

Designation PBS 00 terminal clamps
Clamp
S-bridge
(2 x M5)
M8 screw
V-shaped
(2 x M5)
Picture of clamp
 
 
 
Cross-section of cable
conductors
4 - 70 mm2

cable terminal
max 185 mm2

 
1,5-70mm2
 
1,5-90mm2
Tightening torque  3 Nm  12 Nm  3 Nm

Trade contact

Apator S.A.

 

ul. Żółkiewskiego 21/29,
87-100 Toruń, Poland

Foreign Trade Department Switchgear Equipment

Name:Rafał Kamiński
Function:Area Sales Manager
Phone:+48 (56) 6191 627
Mobile phone:+48 506 009 338
Information:
Central Europe, The Balkans, Turkey (English)
Name:Michael Roclawski
Function:Area Sales Manager
Phone:+48 (56) 6191 492
Mobile phone:+48 506 009 339
Information:
Germany, Austria, Switzerland, Western Europe, Asia, Africa (German)
Name:Grzegorz Błaszkiewicz
Function:Logistics (Russian)
Phone:+48 (56) 6191 316
Mobile phone:+48 506 009 374

Related products:

Copyright © 2009-2010 Apator SA. All rights reserved.Created by VOBACOM