PBS 3
- option of fuse link state indication by neon indicator tube
- labelling area on bus bar terminals acces covers
- labelling clip
- bottom terminal shroud labelling area
Technical data
| Item | |
fuse-base size |
- |
Rated thermal current Ith |
A |
Rated voltage Un |
V |
Rated insulation voltage Ui |
V |
Rated frequency |
Hz |
rated power dissipation |
W |
peak current |
kA |
Mechanical durability |
- |
weight |
kg |
Protection degree |
IP |
Size of fuse links |
- |
| Item | PBS 3 | |
fuse-base size |
- |
3 |
Rated thermal current Ith |
A |
630 |
Rated voltage Un |
V |
690 |
Rated insulation voltage Ui |
V |
1000 |
Rated frequency |
Hz |
50-60 |
rated power dissipation |
W |
60 |
peak current |
kA |
100 |
Mechanical durability |
- |
1000 |
weight |
kg |
5,00 |
Protection degree |
IP |
20* |
Size of fuse links |
- |
3 |
* with fuse link shrouds
Construction
Silver plated contacts provide low power loss. Depending on clamp type,
PBS fuse bases enable user to connect circular or sector-shaped cables or cables with lug terminals. PBS fuse bases of size 1-3 could be equipped with additional fuse link shrouds providing protection degree of IP20. Additionally offered adapters enable to install PBS fuse bases of different sizes on common bus bar system.
PBS fuse bases enable user to connect circular or sector-shaped cables or cables with lug terminals. PBS fuse bases of size 1-3 could be equipped with additional fuse link shrouds providing protection degree of IP20. Additionally offered adapters enable to install PBS fuse bases of different sizes on common bus bar system.
Application
PBS fuse bases are designed for the distribution of electricity and protection against short circuits and overloads in three phase alternative current circuits with maximum operating voltage of 690 V. They are intended for direct installation on horizontal or vertical bus bar system. Due to their modern and compact design installing is easy and gives much saving of space in substations and distribution boards. Each type is suitable for top cable terminal connection when installed on horizontal bus bar system. Removal of the fuse link provides clearly noticeable, large isolating distance in the circuit. Easy installation of earthing devices is another advantage.
Operating conditions
- to be installed in the room free of any dust, aggressive or explosive gases
- altitude up to 2000 meters above sea level
- outdoor - in cabinets with protection degree > IP 34
- ambient temperature from -25°C to +55°C - but in case of use of disconnectors in temperature from +41°C to +45°C current value Ith should be reduced by 5% and within temperature range of +46°C to +55°C current value Ith should be reduced by 10% ,
- relative humidity of the air should not be higher than 50% at temperature of +40°C
Versions
| Version |
Designation | Part number |
|
| PBS 3/630 A | V-shaped cable terminal, 3 x V-terminal clamp (70 - 300 SW) | PBS 3-V | 63-811639-021 |
| PBS 3/630 A | V-shaped cable terminal, 3 x V-terminal clamp (70 - 300 SW) , 3 x fuse link shroud | PBS 3-V-O | 63-811720-021 |
| PBS 3/630 A | A M12 screw terminal, 3 x M12 screw | PBS 3-M | 63-811639-041 |
| PBS 3/630 A | M12 screw terminal, 3 x M12 screw, 3 x fuse link shroud | PBS 3-M-O | 63-811720-041 |
| PBS 3/630 A | V-shaped cable terminal, 3 x double V-terminal clamp (2 x 50 - 240 mm2) | PBS 3-2V | 63-811639-061 |
| PBS 3/630 A | V-shaped cable terminal, 3 x double V-terminal clamp (2 x 50 - 240 mm2), 3 x fuse link shroud | PBS 3-2V-O | non-standard |
| PBS 3/630 A | left side bus bar terminal | PBS 3-NL | 63-811673-021 |
| PBS 3/630 A | left side bus bar terminal, 3 x fuse link shroud | PBS 3-NL-O | non-standard |
| PBS 3/630 A | right side bus bar terminal | PBS 3-NR | 63-811673-041 |
| PBS 3/630 A | right side bus bar terminal, 3 x fuse link shroud | PBS 3-NR-O | non-standard |
PBS 3-V
| |
PBS 3-V-O
| |
PBS with double V-terminal clamps - 2 x 240 mm2
| |
|
PBS with lateral bus bar terminal
| |
|
Clamps
| Designation | PBS 3-V (630 A)
|
PBS 3-M (630 A)
|
PBS 3-2V (630 A) | PBS 3-NL/NR |
|||
| Clamp |
V-terminal clamp 70-300 SW | M12 screw terminal | HS 2/50-240 | M12 screw |
|||
| Picture of clamp |
|
|
|
|
|||
| Cross-section of cable conductors |
V-terminal clamp to direct fixing of conductor with bare end with cross-section: |
cable terminal |
V-terminal clamp to direct fixing of two conductors with bare end with cross-sections: |
lateral bus bar terminal:
left/right |
|||
| 50- 120mm2 |
70 - 150mm2 |
35- 150mm2 |
35 - 185mm2 |
||||
| 70 - 240 mm2 |
95 - 300 mm2 |
50 - 185 mm2 |
50 - 240 mm2 |
||||
| Tightening torque | 30 Nm | 56 Nm | 40 Nm | 56 Nm |
|||
| Bus bars of maximum width of 40 mm and maximum thickness of 8 mm can be fixed to M type screw clamps when protective barrier between phases is applied.
|
|||||||
Trade contact
Apator S.A.
ul. Żółkiewskiego 21/29,
87-100 Toruń, Poland
Foreign Trade Department Switchgear Equipment
Name:Rafał Kamiński Function:Area Sales Manager Phone:+48 (56) 6191 627 Mobile phone:+48 506 009 338 Information: Central Europe, The Balkans, Turkey (English) |
Name:Michael Roclawski Function:Area Sales Manager Phone:+48 (56) 6191 492 Mobile phone:+48 506 009 339 Information: Germany, Austria, Switzerland, Western Europe, Asia, Africa (German) |
Name:Grzegorz Błaszkiewicz Function:Logistics (Russian) Phone:+48 (56) 6191 316 Mobile phone:+48 506 009 374 |