WS-NK, -NKP
- Working temperature and position: 50°C/120°C (H)
- Working pressure: PN 16
- Metrological class: B/A
Multi-jet water meters are designed for measurement of cold and hot
water consumption in buildings with increased demand for medium.
- low starting flow rate
| Item | |
nominal volumetric flow rate |
m3/h |
nominal diameter |
mm |
thread length |
mm |
weight |
kg |
| Item | WS-1.5-NK | WS-1.5-G1-NK | WS-2.5-NK | WS-3.5-NK | WS-6-G1 1/4-NK | WS-6-NK | WS-10-NK | WS-15-NK | WS120-1.5-NK | WS120-1.5-G1-NK | WS120-2.5-NK | WS120-3.5-NK | WS120-6-G1 1/4-NK | WS120-6-NK | WS120-10-NK | |
nominal volumetric flow rate |
m3/h |
1.5 | 1.5 | 2.5 | 3.5 | 6 | 6 | 10 | 15 | 1.5 | 1.5 | 2.5 | 3.5 | 6 | 6 | 10 |
nominal diameter |
mm |
15 | 20 | 20 | 25 | 25 | 32 | 40 | 50 | 15 | 20 | 20 | 25 | 25 | 32 | 40 |
thread length |
mm |
165-G 3/4 | 190-G1 | 190-G1 | 165-G1 1/4, 260-G1 1/4 | 260-G1 1/4 | 260-G1 1/2 | 300-G2 | 300* | 165-G 3/4 | 190-G1 | 190-G1 | 260-G1 1/4 | 260-G1 1/4 | 260-G1 1/2 | 300-G2 |
weight |
kg |
1.9 | 2.2 | 2.2 | 2.9 | 2.9 | 3.1 | 5.1 | 10.3 | 1.9 | 2.1 | 2.1 | 2.9 | 2.9 | 3.5 | 5.1 |
* version with flanges
remote volume read-out (NK)
water meters equipped for fitting pulse transmitter (NKP)
(for cold water)
- mounting on pipelines in horizontal position with counter set upwards -H,
- metrological class: B or A,
- low starting flow rate,
- easy read-out faciliated by an adjustable rotary counter,
- pulse transmitter NK -remote reading transmission,
- a counter of a pointer - roller type set in dry space,
- a magnetic clutch that transmits impeller's rotation from wet to dry space,
- possibility of electronic check-up,
- materials approved for contact with potable water,
- resistance to an external magnetic field,
- approval of The Central Measurement Office,
- conformity with standards ISO 4064, BS 5728.