MNK, MNK-RP
- Working temperature and position: 50 °C (H)
- Working pressure: PN 16
- Metrological class: B/C
Wet multi-jet vane-wheel water meters are fully resisant to an influence of external magnetic field.
- low starting flow rate
| Item | |
nominal volumetric flow rate |
m3/h |
nominal diameter |
mm |
thread length |
mm |
weight |
kg |
| Item | MNK-1,5 | MNK-1,5 G1 | MNK-2,5 | MNK-3,5 | MNK-6 G1 1/4 | MNK-6 | MNK-10 | MNK-15 | |
nominal volumetric flow rate |
m3/h |
1.5 | 1.5 | 2.5 | 3.5 | 6 | 6 | 10 | 15 |
nominal diameter |
mm |
15 | 20 | 20 | 25 | 25 | 32 | 40 | 50 |
thread length |
mm |
110, 145, 165 | 190-G1 | 190-G1 | 260-G1 1/4 | 260-G1 1/4 | 260-G1 1/2 | 300-G2 | 300 kołnierz |
weight |
kg |
1.5 | 2.0 | 2.0 | 3.0 | 3.0 | 3.0 | 5.0 | 9.0 |
- hermetically sealed roller chamber (RP)
- mounting pipelines in horizontal position with counter set upwards - H,
- a counter of pointer - roller type,
- possibility of electronic check-up,
- materials approved for contact with potable water,
- possibility of back-flow valves fitting,
- type approval EEC,
- conformity with standards ISO 4064, BS 5728.